垂直分液漏斗振荡器价格,数显分液漏斗振荡器报价,甘肃庆阳分液漏斗振荡器生产厂家
- 型号:QYLDZ-6
- 产地:中国大陆
- 供应商:上海乔跃电子有限公司
- 供应商报价:12500
- 标签:垂直分液漏斗振荡器价格,数显分液漏斗振荡器报价,甘肃庆阳分液漏斗振荡器生产厂家,生命科学,生物工程设备,供应垂直分液漏斗振荡器价格,数显分液漏斗振荡器报价,甘肃庆阳分液漏斗振荡器生产厂家,上海乔跃电子有限公司
分液漏斗振荡器价格,数显分液漏斗振荡器生产批发
规格型号:QYLDZ-6
产品说明:振荡速度:10~300次/分钟
联 系人:刘俊
电 话:183 2100 4009
Q Q:2851513071
分液漏斗振荡器(又称萃取振荡器),是为提高萃取净化效率而设计的。该产品具有振荡频率和振荡角度可调、定时时间长、频率和定时数字显示、多种样品架等功能,能大大提高萃取净化的效率,减轻工作强度。产品操作安装简便,可满足各种类型实验室萃取净化的需要。
【振荡器主要特征】:
●分液漏斗振荡器可选择倾斜振荡和垂直振荡两种振荡方式,可以得到更大的混合力。
●振荡频率数字显示,开机后可显示上次关机前的振荡次数。可以切换定时振荡和连续振荡。
●振荡频率为无级变速,倾斜时振荡频率可达20~250次/min,垂直时振荡频率可达20~300次/min。
●启动缓冲和停机缓冲技能,启动及停止缓慢进行,减少对分液漏斗的冲击。
●分液漏斗振荡器振荡时,运行声音在55分贝以下,无噪音,非常安静。
●使用直流马达,可长时间保持稳定的振荡频率。
●分液漏斗夹具使用方便,安装或取下分液漏斗十分方便。
【垂直倾斜振荡器技术参数】:
◆振荡方式:垂直或倾斜振荡
◆倾斜角度:0~22°可调
◆振荡速度:10~300次/分钟
◆振荡幅度:45mm
◆负荷:约7Kg×2(含夹具)
标准配置:
振荡器主机:1台,标准夹具:6个(150ml~1000ml)之内,夹具规格可定制。
【萃取振荡器用途】:
1、环境分析前处理的提取操作
2、食品、油脂天然物的提取
3、农药残留提取
4、土壤中有害物质的提取
5、水质污染检测的提取
1. Due to the constant contact with acid, alkali and water, and the instrument has 220V ac, the laboratory socket must have a good grounding.
2. After each use of the instrument, apply the filter paper to drain the water from the filter base.
3, when the crucible in 500 ℃ high temperature furnace burning after 1 hour, don't immediately remove the crucible, be careful in furnace temperature and furnace temperature of the temperature difference is too big to make the crucible.
4. When handling the lifting handle, pay attention to the slow improvement of the handle, while paying attention to the right of the upper and lower glass mouth to prevent improper operation and damage the instrument.
5. When it is difficult to extract filter, it is recommended to use vacuum pump to filter and see the schematic diagram.
6. Use distilled water for the first time when you are not familiar with it, and then draw off to do the experiment.
After finished 7, using the instrument, it is best to the flasks acid, alkali poured out, again add tap water in the bottle, the crucible mount, adding water respectively in the crucible, and then removed respectively, with washing line.
8, after get the test results, in order to remove residues in the samples, the crucible core crucible should be in the 30% - 50% concentration of hydrochloric acid solution soak for a few hours, and then after drying, water washing for next time use.
9. Please pay attention to safety during operation, with thick latex gloves and gloves to prevent acid and alkali from touching the hands. When taking out the crucible, wear a cloth glove and be careful to burn your hands.
【产品相关