| 是否提供加工定制: | 否 | 品Pai: | 日本横河 |
| 型号: | OX100系列 | 类型: | 在线式氧气检测仪 |
| 测量范围: | 0-PPM | 测量对象: | 氧气 |
| 测量精度: | ±15 ppm (Meas. range : 20-100 ppm), ±25 ppm (Meas. range : 100-1000 ppm), | 电压: | AC100-240V(v) |
| 分辨率: | +-15 0.3% 7.5% | 尺寸: | 96*96*113(mm) |
| 重量: | 5(kg) | 电源: | AC |

% range).Calibration 1. Atmospheric pressure calibration (between 15 to 25% O2) 2. 1000 ppm standard gas calibration (1000±50 ppm)Analog output 4-20 mA DC isolated, fixed range (0-1000 ppm or 0-25%),(for 0-25%, 4 mA DC corresponds to 1500 ppm or less).Contact output Two outputs, rated 250 V AC, 1 AHi or Lo alarm, sensor disconnectd alarmAlarm output High alarm contact output if concentration abnormalHi or Lo alarm (depending on specification), setting range : 1 ppm to 24.9%Self-diagnostics Sensor disconnectedPower supply 100 V AC ±10%, 50/60 Hz, 15 VAConverter size 96 x 96 x 190 mmLimiting-current typeNatural diffusionTemperature 0 - 70°C, Humidity 20 - 80% RH (dew free), Pressure 1013 ± 40 hPa (Abs)O2 in N2 or mixed gases; cannot be used with silicone vapor, combusible gases or organic solventsIndoor, panel mounting0-100 ppm / 0-1000 ppm / 0-10000 ppm / 0-25%, automatic / fixed switching mode±15 ppm (Meas. range : 20-100 ppm), ±25 ppm (Meas. range : 100-1000 ppm),±0.3%of reading (Meas. range : 1000-5000 ppm),±7.5% of reading (Meas.range : 5000-10000 ppm), ±0.25% (Meas.range : 1-25%)1. Atmospheric pressure calibration (between 15 to 25% O2)2. 100 ppm calibration (between 80 and 120 ppm)3. 1000 ppm calibration (between 900 and 1100 ppm)4. 9000 ppm calibration (between 8500 and 9500 ppm)5. Atmospheric pressure, 20, 100, 500, 1000 and 9000 ppm calibrationThe measuring value can be adjusted to true analyzed value.1. 4-20 mA DC isolated, fixed range(0-100, 0-1000, 0-10000 ppm, 0-25% selectable),or 4-20 mA DC autoranging.2. 1-5 V DC, fixed range (0-100, 0-1000, 0-10000 ppm, 0-25% selectable)3. Zone signal output for 4-20 mA DC autorangingTwo outputs, rated 110 V AC, 24 V DC, 1 AHi or Lo alarm, sensor disconnected alarmHi or Lo alarm. setting range : 1 ppm to 24.9%.Sensor disconnectedSensor and converter temperature 0 to 70°C (dew free)100-240V AC ±10%, 50/60Hz 15VA96 x 96 x 190 mmMeas. principleSamplingGas sampleMeasured gasMountingMeas. rangesunitGas outlet cock (with flow adjuster): qty. oneGas outlet cock (without flow adjuster): qty. oneStandard gas cylinder ( 1000 ppm O2/N2 ) : qty. sixSensor assy. cable 3 m for OX100 onlyExtension cable, 2 m: for OX100 onlyBracket for mounting OX100, two per set.Sensor assy. One per set : for OX102 onlyExtension cable, 4 m: for OX102 onlyExtension cable, 9 m: for OX102 onlyExtension cable, 29 m: for OX102 onlySensor holder (metal) for OX100 or OX102Sensor holder (plastic) for OX100 or OX102L9811LA plastic resin sensor holder is provided as standard accessory.*1 For measurement in the range of 1500 to 4500 ppm, use the OX102.*Standard Product does not have a sensor holder. To get the sensor holder, specify " /S " or " /J".(If using Sampling Unit, the sensor holder is not required.)RepeatabilityCalibrationFine tune modeAnalog outputContact outputAlarm outputSelf-diagnosticsStorage environmentStorage environment Sensor and converter temperature 0 to 70°C (dew free)Power supplyConverter sizeModel OX100Limiting-current typeNatural diffusionTemperature 0 - 70°C, Humidity 20 - 80% RH (dew free), Pressure 1013 ± 40 hPa (Abs)O2 in N2 or mixed gases; cannot be used with silicone vapor, combusible gases or organic solventsIndoor, panel mountingMeas. principleSamplingGas sampleMeasured gasMountingOX100 measuring principles, measured gas, and system configuration are same as for OX102