西门子6ES7241-1AH32-OXBO
- 供应商:上海启水自动化科技有限公司
- 供应商报价:面议
- 标签:西门子6ES7241-1AH32-OXBO,-1,上海启水自动化科技有限公司
产地类别 | 进口 |
---|
西门子6ES7241-1AH32-OXBO
我公司经营西门子 PLC;S7-200S7-300 S7-400 S7-1200 触摸屏,变频器,6FC,6SNS120 V10 V60 V80伺服数控备件:原装进口电机(1LA7、1LG4、1LA9、1LE1),国产电机(1LG0,1LE0)大型电机(1LA8,1LA4,1PQ8)伺服电机(1P,1PM,1FT,1FK,1FS)西门子保内全
新原装产品‘质保一年。一年内因产品质量问题免费更换新产品;不收取任何费。咨询。
上海晋营自动化科技有限公司销售西门子千万余产品 尽新老顾您来询价订货采购,欢迎您来晋营公司,谢谢您的光临!您的合作是我Z大的荣幸!Tank you very muc!
上海晋营自动化科技有限公司
:乔 静
电 话:(同号)
邮 箱:3548508227
:3548508227
SIMATIC S7-1200,CPU 1212C, 紧凑型 CPU,AC/DC/继电器, onboard I/O: 8 DI DC 24V;6 DO 继电器 2A; 2 AI 0-10V DC, 电源:交流 85-264V AC bei 47-63Hz, 程序/数据存储器 75 KB | ||
一般信息 电 话:(同号) | ||
产品类型标志 | CPU 1212C AC/DC/继电器 | |
固件版本 | V4.2 | |
附带程序包的 | ||
● 工程系统 | STEP 7 V14 以上 | |
电源电压 | ||
额定值 (AC) | ||
● AC 120 V | 是 | |
● AC 230 V | 是 | |
允许范围,下限 (AC) | 85 V | |
允许范围,上限 (AC) | 264 V | |
电源频率 | ||
● 允许范围,下限 | 47 Hz | |
● 允许范围,上限 | 63 Hz | |
输入电流 | ||
耗用电流(额定值) | 在 AC 120 V 时 80 mA;在 AC 240 V 时 40 mA | |
耗用电流,Z大值 | 在 AC 120 V 时 240 mA;在 AC 240 V 时 120 mA | |
接通电流,Z大值 | 20 A; 264 V 时 | |
I2t | 0.8 A2·s | |
输出电流 | ||
用于背板总线 (DC 5 V),Z大值 | 1 000 mA; Z大 5 V DC,用于 SM 和 CM | |
传感器供电 | ||
24 V 传感器供电 |
● 24 V | 20.4 至 28.8V | |
功率损失 | ||
功率损失,典型值 | 11 W | |
存储器 | ||
工作存储器 | ||
● 集成 | 75 kbyte | |
● 可扩展 | 否 | |
装载存储器 | ||
● 集成 | 2 Mbyte | |
● 插拔式(SIMATIC 存储卡),Z大值 | 带有 SIMATIC 存储卡 | |
缓冲 | ||
● 存在 | 是 | |
● 免维护 | 是 | |
● 不带电池 | 是 | |
CPU-处理时间 | ||
对于位运算,典型值 | 0.085 μs; / 说明 | |
对于字运算,典型值 | 1.7 μs; / 说明 | |
对于浮点运算,典型值 | 2.3 μs; / 说明 | |
CPU-组件 | ||
组件数量(总计) | DBs、FCs、FBs、计数器和定时器。可设定地址的模块数量可从1到65535。可不受限制用于整个工作存储器 | |
OB | ||
● 数量,Z大值 | 只通过代码工作存储器进行限制 | |
数据范围及其剩磁 | ||
保留的数据范围(包括时间、计数器、标记),Z大值 | 10 kbyte | |
标记 | ||
● 数量,Z大值 | 4 kbyte; 标记范围的大小 | |
本地数据 | ||
● 每个优先等级,Z大值 | 16 kbyte; 优先级等级 1(程序周期):16 KB,优先级等级 2 至 26:6 KB | |
地址范围 | ||
过程映像 | ||
● 输入端,可调整 | 1 kbyte | |
● 输出端,可调整 | 1 kbyte | |
硬件扩展 | ||
每个系统的组件数量,Z大值 | 3 个通讯模块、1 个信号板、2 个信号模块 |
西门子6ES7241-1AH32-OXBO
拥有工业识别领域内完整和可扩展的产品系列,可实现灵活和经济的解决方案。
切换书签:设置或移除书签,单击该按钮,在当前光标指定的程序网络设置或移除书签。在程序中设置书签,书签便于在较长程序中指定的网络之间来回移动。如图10所示。
输入模块的RC滤波电路用来滤除由输入端引入的干扰噪声,消除因外接输入触点动作时产生的抖动引起的不良影响,滤波电路的时间常数决定了输入滤波时间的长短,其典型值为10ms左右。
可使用动态制动来提高制动性能
电压范围宽,具有先进的冷却设计,涂覆印刷电路板设计提高了变频器在恶劣环境中的耐用性
西门子PLC模块CPU1212C
输送系统
诊断功能可以用来判断模块的信号采集(针对数字量模块)或者模拟量处理(针对模拟模块)是否工作于无故障状态。在诊断分析中,必须区分可参数化和非参数化诊断消息: 非参数化诊断消息:
滤波器
当关机点动开关或电动机电路断路器(分别与输入点I0.1和I0.2连接)动作时,电动机关机。如果开机开关和关机开关同时动作,电动机仍然处于关机状态。 在用户窗口将水平分裂条下拉即可显示局部变量表,将水平分裂条拉至程序编辑器窗口的顶部,局部变量表不再显示,但仍旧存在。
西门子PLC模块CPU1212C
发生电源故障后自动重启和快速重启,可用性极高 ZY控制器和3个扩展机架Z多可连接32个模块: 通过IM 460-3和IM 461-3进行远程链接
12 英寸,带薄膜按键,分辨率: 800 x 600 像素
- Allen Bradley PLC5/-11, 20, 30, 40, 60, 80 (DF1 协议 )
l ---|NOT|---Invert Power Flow RLO取反
2)从工作方式上看,在继电器控制电路中,当电源接通时,电路中所有继电器都处于受制约状态,即该吸合的继电器都同时吸合,不该吸合的继电器受某种条件限制而不能吸合,这种工作方式称为并行工作方式。而PLC的用户程序是按一定顺序循环执行,所以各软继电器都处于周期性循环扫描接通中,受同一条件制约的各个继电器的动作次序决定于程序扫描顺序,这种工作方式称为串行工作方式。
一是PLC网络化技术的发展,其中有两个趋势:一方面,PLC网络系统已经不再是自成体系的封闭系统,而是迅速向开放式系统发展,各PLC除了形成自己各具特色的PLC网络系统,完成设备控制任务之外,还可以与上位计算机管理系统联网,实现信息交流,成为整个信息管理系统的一部分;另一方面,现场总线技术得到广泛的采用,PLC与其他安装在现场的智能化设备,比如智能化仪表、传感器、智能型电磁阀、智能型驱动执行机构等,通过一根传输介质(比如双绞线、同轴电缆、光缆)连接起来,并按照同一通信规约互相传输信息,由此构成一个现场工业控制网络,这种网络与单纯的PLC远程网络相比,配置更灵活,扩容更方便,造价更低,性能价格比更好,也更具开放意义。 西门子PLC模块CPU1212C
每个用户程序Z多 200 个函数块
SICLOCK time synchronization
System description
Salites or long-wave transmitters are used as primary time sources. The SICLOCK wireless receivers (e.g. SICLOCK GPS1000) receive these high-frequency signals and transmit the demodulated time signal to the central plant clock via a robust and interference-proof 2-wire connection.
The central plant clock converts the time signal into an Ethernet-based network frame (e.g. NTP, SIMATIC procedure) and thus provides all connected network stations with precise and uniform time information.
Furthermore, in the event of failure or loss of reception from the primary time source, the central plant clock ensures stable continuation of the clock time and tracking of the system time without time jumps as soon as reception is restored.
SICLOCK TC400 central plant clock with SICLOCK GPS1000 wireless receiver
Application examples
System with GPS reception
SICLOCK TC400 central plant clock with SICLOCK GPS1000 wireless receiver
The SICLOCK GPS1000 wireless receiver (Article No. 2XV9450‑1AR84) is used in this example. The wireless receiver is mounted outdoors with "visual contact" to the navigation salites for optimum reception quality.
The line current method (TTY - 20 mA) used in the SICLOCK system permits distances of up to one kilometer between the wireless receiver and the central plant clock and also supplies the receiver with power, which eliminates the need for any additional power supply components. This makes it possible to install the central plant clock at a central location, even in plants spread over a very large area.
The SICLOCK TC400 central plant clock shown in the example features four 10/100 Mbit Ethernet interfaces for supplying up to four independent IP networks. The SICLOCK TC100 central plant clock with one Ethernet interface has been designed for smaller, cost-sensitive plants.
The central plant clocks do not have Ethernet switching functionality for safety reasons. SIMATIC NET SCALANCE X switches are recommended for this purpose, see http://support.automation.siemens.com/WW/view/en/18689247/133200.
System with DCF77 reception
SICLOCK TC400 central plant clock with SICLOCK DCFRS wireless receiver
As an alternative to receiving salite signals, the DCF77 time signal transmitter can be used as primary time source. The transmitter is located near Frankfurt am Main and transmits long-wave signals at a frequency of 77.5 kHz. Under normal conditions, reception is possible up to a distance of about 1 500 km from the transmitter.
The SICLOCK DCFRS wireless receiver with TTY output (Article No. 2XV9450‑1AR16) is used in this application. Here too, a separate power supply is not required if a SICLOCK TC100 or SICLOCK TC400 central plant clock is used.
The advantages over salite reception are lower costs and the option of mounting the receiver inside a building. The last advantage is especially useful if outdoor installation is not advisable, e.g. due to risk of vandalism.
Redundant modes
Due to the importance of having a reliable time supply in many demanding applications, the SICLOCK system offers optional redundant modes to further increase plant reliability. The redundancy can be on the reception side, the network side, or even be combined with a redundant central plant clock for highly sensitive applications.
Reception-side redundancy
SICLOCK TC400 central plant clock with SICLOCK GPS1000 and SICLOCK DCFRS wireless receivers
In this application, SICLOCK GPS1000 and SICLOCK DCFRS wireless receivers are used in parallel. External time information can continue to be received even if one of the two primary time sources fails. The SICLOCK TC100 and SICLOCK TC400 central plant clocks each have two inputs for the wireless receivers.
Highly redundant system
SICLOCK TC400 central plant clocks with SICLOCK GPS1000 wireless receiver
This application can satisfy the highest redundancy requirements. The system uses two SICLOCK TC400 central plant clocks, each with separate SICLOCK GPS1000 wireless receivers
One central plant clock is parameterized as the NTP server master, the other as the NTP server slave. The NTP server slave takes over if the NTP master or the connected wireless receiver fails.
If SICLOCK GPS1000 wireless receivers are used, they should be mounted as far away from each other as possible so that the receiver with the better reception conditions can be used and, for example, to avoid damage to both receivers in the event of a lightning strike. Instead of using two GPS wireless receivers, one SICLOCK DCFRS wireless receiver can of course be used.
Synchronization of IT networks
IT network with a central plant clock
德国西门子(SIEMENS)公司生产的可编程序控制器在我国的应用也相当广泛,在冶金、化工、印刷生产线等领域都有应用。西门子(SIEMENS)公司的PLC产品包括LOGO、S7-200、S7-1200、S7-300、S7-400等。 西门子S7系列PLC体积小、速度快、标准化,具有网络通信能力,功能更强,可靠性高。S7系列PLC产品可分为微型PLC(如S7-200),小规模性能要求的PLC(如S7-300)和中、高性能要求的PLC(如S7-400)等。
西门子SIMATIC系列PLC,诞生于1958年,经历了C3,S3,S5,S7系列,已成为应用非常广泛的可编程控制器。
西门子(SIMATIC)PLC的6代
1、西门子公司的产品Z早是1975年投放市场的SIMATIC S3,它实际上是带有简单操作接口的二进制控制器。
2、1979年,S3系统被SIMATIC S5所取代,该系统广泛地使用了微处理器。
3、20世纪80年代初,S5系统进一步升级——U系列PLC,较常用机型:S5-90U、95U、100U、115U、135U、155U。
4、1994年4月,S7系列诞生,它具有更国际化、更高性能等级、安装空间更小、更良好的WINDOWS用户界面等优势,其机型为:S7-200、300、400。
5、1996年,在过程控制领域,西门子公司又提出PCS7(过程控制系统7)的概念,将其优势的WINCC(与WINDOWS兼容的操作界面)、PROFIBUS(工业现场总线)、COROS(监控系统)、SINEC(西门子工业网络)及控调技术融为一体。
6、西门子公司提出TIA(Totally Integrated Automation)概念,即全集成自动化系统,将PLC技术溶于全部自动化领域。
由Z初发展至今,S3、S5系列PLC已逐步退出市场,停止生产,而S7系列PLC发展成为了西门子自动化系统的控制核心,而TDC系统沿用SIMADYN D技术内核,是对S7系列产品的进一步升级,它是西门子自动化系统Z,功能Z强的可编程控制器。
产品 | 电池模板 2.5 Ah |
订货号 | 6EP1 935-6MD31 |
充电电流/充电电压 | 免维护纯质铅蓄电池 |
推荐充电终止电压(备用用途)取决于电池温度 | 29.0 V,+10℃ 时; |
推荐充电电流 | Z大 5 A |
保护 | |
短路保护 | 电池熔断器 15 A/32 V |
电池保护 | 阀门控制 |
安全 | |
保护类别 | III 类 |
UL/cUL (CSA) 认证 | cURus 认证 (UL 1778, CSA C22.2 No. 107.1), File E219627 |
防护等级 (EN 60529) | IP00 |
操作数据 1) | |
环境温度范围 | ‑40 ... +60 °C 自然对流 |
运输和贮存温度 | ‑40 ... +60 °C |
自放电率 | 20 ºC 电池温度下,每月约 3 % (随温度上升而增加) |
使用寿命 2) | |
铅蓄电池的使用寿命 (当容量低于初始的50%时) | +20 °C时,约10年 |
机械机构 | |
连接 | 1 个螺钉型接线端子,每个 0.08 -2.5 mm2,用于 +BAT 和 -BAT |
供给附件 | 包括1 固态电流熔断器的附件包 |
外形尺寸(宽 x 高 x 深),[mm] | 265 x 151 x 91 |
重量,约 | 约 3.8 kg |
安装 | 卡装至 DIN 导轨 EN 60715 35x7.5/15 或锁眼安装,适合钩到 M4 螺钉上 |
1)在存储、安装或操作这种铅蓄电池时,必须遵照 DIN/VDE 及有关的国家规程(VDE 0510 Part 2/EN 50272-2)中规定的规范。必须为电池提供足够的通风;必须离开潜在的火源至少 50 cm 的距离。
2) 除了存储和工作温度外,其它因素,如存储期限、存储期间充电状态也对电池的可能使用寿命有决定性影响。因此,电池贮存时间应尽可能短,始终充满电,并处于温度范围 0 - +20℃ 范围内。
产品 | 电池模板 2.5 Ah |
订货号 | 6EP1 935-6MD31 |
充电电流/充电电压 | 免维护纯质铅蓄电池 |
推荐充电终止电压(备用用途)取决于电池温度 | 29.0 V,+10℃ 时; |
推荐充电电流 | Z大 5 A |
保护 | |
短路保护 | 电池熔断器 15 A/32 V |
电池保护 | 阀门控制 |
安全 | |
保护类别 | III 类 |
UL/cUL (CSA) 认证 | cURus 认证 (UL 1778, CSA C22.2 No. 107.1), File E219627 |
防护等级 (EN 60529) | IP00 |
操作数据 1) | |
环境温度范围 | ‑40 ... +60 °C 自然对流 |
运输和贮存温度 | ‑40 ... +60 °C |
自放电率 | 20 ºC 电池温度下,每月约 3 % (随温度上升而增加) |
使用寿命 2) | |
铅蓄电池的使用寿命 (当容量低于初始的50%时) | +20 °C时,约10年 |
机械机构 | |
连接 | 1 个螺钉型接线端子,每个 0.08 -2.5 mm2,用于 +BAT 和 -BAT |
供给附件 | 包括1 固态电流熔断器的附件包 |
外形尺寸(宽 x 高 x 深),[mm] | 265 x 151 x 91 |
重量,约 | 约 3.8 kg |
安装 | 卡装至 DIN 导轨 EN 60715 35x7.5/15 或锁眼安装,适合钩到 M4 螺钉上 |
1)在存储、安装或操作这种铅蓄电池时,必须遵照 DIN/VDE 及有关的国家规程(VDE 0510 Part 2/EN 50272-2)中规定的规范。必须为电池提供足够的通风;必须离开潜在的火源至少 50 cm 的距离。
2) 除了存储和工作温度外,其它因素,如存储期限、存储期间充电状态也对电池的可能使用寿命有决定性影响。因此,电池贮存时间应尽可能短,始终充满电,并处于温度范围 0 - +20℃ 范围内。