产品库

ZY6006 火花试验机

产品信息
ZY6006火花试验机
Spark tester
一、仪器图示 Instrument graphic
二、使用范围Using range
本试验机适用于PVC、PE、硅胶、橡胶等电线之被覆的针孔检查测试。使用于押出机生产线上检验或成品包装过程之检验,符合GB/T3048、9-94、UL1581检验标准。 
This machine is suitable for PVC, PE, silicone, rubber covering of a pinhole test of electric wire and so on. Used for extruding machine production line inspection and product packaging process of inspection, in line with the GB/T3048, 9-94, UL1581 testing standard.
三、性能参数 The performance parameters
2.1、该机包括高压电源、试验电极、电压表、击穿报警及必要 的电气设施和连接线。  
2.2、灵敏度:在5KV,其火花间隙短路状态下稳态电流≤60 μA;5KV被试验线材与珠链间隙大于2.5mm以上,时间为0.15s时,可检测出不良。  
2.3、稳定性:在20次击穿次数时为。 
2.1, the machine including the high voltage power supply, breakdown alarm test electrode, voltmeter, and the necessary electrical facilities and cable.
2.2, sensitivity: in 5 kv, the spark gap acuities were 60 mu A steady state short circuit conditions current; 5 kv is test wire and bead chain gap is greater than 2.5 mm above, when time is 0.15 s, can detect the bad.
2.3, stability: when breakdown times 20 times.
四、安装 The installation
1、 安装时须将电极槽推置于与被测电线成一直线,线16导轮沟底与电线接触,调整螺杆使线在ZX正确位置。      
2、电线必须从珠链里穿过。  
3、机壳外部必须用3.5mm2之导线与其它附属设备之接地端子做良好接地施工17。  
4、电极槽内被测试之电线,所含水份必须以吹拭器用气压除湿。 
1, when installation should be pushed electrode groove on with wire to be tested in a straight line, line 16 idler pulley groove and the contact wire, adjustment screw make the line in the center of the correct position.
2, the wire must be through the bead chain.
3, casing external must use was 3.5 wire and other accessory equipment grounding terminal to do well the construction of 17.
4, electrode wire slot under test, the water must be dry is used to blow air dehumidification.
五、操作 operation
本机安装妥后须先装1电极槽之盖闭后,使安全开关接触,将计数器归零,将7电源开关置于“ON”位,8指示灯亮,按下高压
Shall be installed within the machine after installation completed 1 after the lid closed of electrode groove, make the safety switch contact, to the counter to zero and puts 7 power switch "ON" position, 8 indicator, press and high pressure
六、注意事项 Matters needing attention
1、 电极箱1可与2本体分开安装,但高压引线必须使用高压电线,不得使用同轴电缆。 
2、 高压引线须使用绝缘保护。 
3、 本体必须与机器设备连锁接地。 
1, electrode box 1 and 2 ontology separately installed, but high-voltage fuses high-voltage wire must be used, coaxial cable shall not be used.
2, high voltage fuses shall be used for insulation protection.
3, ontology must chain with machinery and equipment grounding.
信息声明:本产品供应信息由仪器网为您整合,供应商为(东莞中诺台湾质检仪器设备有限公司),内容包括 (ZY6006 火花试验机)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (ZY6006 火花试验机)的信息,请直接联系供应商,给供应商留言!