产品库

西班牙原装进口魔术焕肤枪哪里买

产品信息
西班牙原装进口魔术焕肤枪哪里买 广州西班牙魔术焕肤枪厂家

西班牙魔术焕肤枪英文说明资料 西班牙原装进口魔术焕肤枪




3-INSTALLATION


The device installation is extremely user friendly and
easy:


  1- Remove the
CooLifting Gun base and the power connector from


    the
briefcase.


  2-Place the
base on a flat surface in the treatment room near a power outlet.


  3-Connect the
Gun base through its front side


    to the base
logo will turn on and the power


    Connector.


4-Place the Gun on its base to start charging


 It.the base
logo will turn on and the screen


 Will display
the charge action


5-After the gun is charged,the base logo will turn
off.


6-Place the ”kits next to the Gun base
,so that they can be


Easily reached when starting a treatment.


 


 


 


 


 


 


 


4-SESSION
PREPARATION


The following Warning screen will be displayed if the
cosmetic solution


vial and gas cartridge are not properly installed
before starting a treatment. It is important to note that the the Gun will not
be enabled


until detects that everything is properly loaded


                   


1-Take one of the
treatment kits from the  units display
box and open it. Take the CooLifting cosmetic product bottle out and remove the
blue cover.A rubber cover surrounded by a metal ring will become Visible.


 


 


 


 


2-Remove the gun from its base and attach the hand
strap to it.


Both the gun logo and the screen will turn on. Place
the container in its place ,in the upper part of the gun ,with the rubber cover
facing


Downwards, pressing on it until needles penetrate
rubber cover.


 


3-Remove the cartridge
from its box and screw it quick and tightly on the CooLifting Gun back side ,to
the top , going over the first stop ,so


That it is secure. Never remove the cartridge by
unscrewing it in this


Phase or any other situation until the 4 full minutes
of spray have


Ended.


          


When everything is ready.the gun will display the
CooLifting screen.


           


NOTE: if left away from the base,after two minutes it
will go on to stand-by and,after 5minutes .it will turn itself off .you can
leave the


Stand-by status by pressing any button, the Gun the same
state it was


in before going into standby.if it has turned itself
off, you must return


It to the base and the CooLifting screen will be
displayed again.


You are now ready to start the treatment session.


                  
importANT!!


Inserting the Cosmetic Solution:


Press as shown in the picture below. DON’T TURN or TWIST the bottle
of the cosmetic solution as it may damage the Gun


                 


Removal of the Cosmetic Solution after the Treatment
Using two fingers pull the vial directly out as shown in the picture below.DON’T TURN or TWIST the bottle
of the cosmetic product in order to prevent


Damage to the Gun


  


 


5-THE SESSION


Note:


If the Gun is not going to be used immediately, do
not insert a new  vial of
cosmetic product and cartridge into the dispenser.


only place the cosmetic product bottle and the
cartridge just prior to a treatment.


Never place the Gun with the cosmetic product bottle and
the cartridge on the charger base .once a Gun has a new vial of Cosmetic
Solution and gas cartridge installed it must be emptied before it is placed
back on the charger.Leaving the cosmetic solution vial in the unit will cause
issues with the software .Contact Customer Service if you have any
questions.Additionally,never remove the gas cartridge unless it has been
used and emptied.


HOW TO PEREORM A COOLIFTING TREATMENT:


Clean any make-up from the patient’s face before starting .


  After having the Gun prepared with cosmetic
solution and gas cartridge,invite the


client into the treatment room. To begin the
treatment, prepare the client on the


Treatment table in a laying or half-laying position,at
a height so that the Gun will


Always point down.


To start the treatment,the“Session”screen will be displayed.in order to get started,the padlock button must be selected to unlock it.

 

 

 

 

                          Padlock button

After it is unlocked,press the trigger without releasing it and the warm-up screen will be displayed, with a 10 seconds count-down.After this count down the Gun 

Will pulse the spray which contains the contents of the cosmetic solution and the

cool gas at the same time. The screen will display the remaining session time,counting down from 4 minutes.

If the padlock hasn’t been previously unlocked, upon pressing the trigger the padlock hasn’t been previously unlocked, upon pressing the trigger the following

Warning screen will be displayed:

              

The application must be done continuously always moving during the application of the cosmetic solution. The suggested dispense distance from the skin is O.5-1 cm (0.18 to 0.39 inches).If a client is uncomfortable simply move the spray further

Away from the skin.. It is recommended to have the client protect their eyes during the treatment ideally using protective glasses or a cover.Never touch the surface of the skin with the unit!

 

 

 

 

We recommend starting the treatment from the ear area toward the neck. Use small circular movements working your way around the face.Ensure you dispense

the cosmetic solution over entire face and then repeat apply on any areas of concern.The treatment must be carried on for the full 4 minutes,from start to finish,without releasing the Gun trigger and without any interruptions.Each treatment session that would lose its effect if interrupted. In the beginning the spray will be strongest and will weaken during the final minute .Clients should also

be advised about the“clicking”noise made by the Gun during the treatment.

The Gun will automatically stop at the end of the treatment session,after 4 minutes.The screen will display “End of session”and a“beep-beep”sound will

Indicate that the gas cartridge and the cosmetic solution bottle can be removed.

                                        The sound will continue until both the gas cartridge and cosmetic solution bottle 

  Have been removed.

  NOTE: if the trigger is released, the session pauses and restarts upon pressing the 

 trigger again ,with the remaining session time that was left before the interruption.

 If the pause is done within a few seconds of a session,upon pressing the trigger 

 Again it will also restart where it was stopped , but with another 10 seconds warn

 -up.

 once a treatment is complete, proceed to a soft facial massage during 2-3 minutes;

 It will help removing the product excess.

 You should expect that a short hiss of air when unscrewing the gas cartridge after a

 completed treatment. Remember:Do not remove either the cosmetic solution 

 bottle or gas cartridge until the full 4  minutes are done ! 

 NOTE: The Gun must be charged after 4 to 5 treatments. The software will not 

 Allow you to begin treatment unless the dispenser is sufficiently charged.

 6-PROTOCOL:NUMBER OF TREATMENTS AND APPLICATION ZONES

There are some general to be used as guidelines,but they must be adapted to each

clients’s desired outcomes and be its most affected zones: 

-Single session: Immediate effect in a single session on symptoms, more radiant

Appearance and encouraged hydration of the skin.

-Multiple treatment protocol: 6-8 sessions in one month (1-2 per week) for a more

Youthful appearance, increased longer lasting radiant appearance, encouraged

Hydration of the skin.

-Maintenance treatment: One session every 2 weeks.

The application zones are:

-Around the eyes (do not apply on the eyelids)

-Forehead

-Brow

-Cheeks

-Zone around the lips the whole orbit round the mouth ,above, below and on both sides.

 


      

7--SAFETY WARNINGS AND PRECAUTIONS

  -CO2 Gas Cartridge

     - Always use the Gun with the hand strap for the duration of the treatment once the gas cartridge is inserted.

     -Turn the cartridge clockwise rapidly screwing it into the dispenser.

     -once inserted, do not try for any reason to unscrew the gas cartridge until the

      Treatment is complete.If you think something is wrong,discharge the spray gas by pressing the trigger of the CooLifting Gun till the gas flow stops.Direct the gas flow away from yourself and be sure that the cartridge is empty before attempting to remove it.

     -Improper insertion of the gas cylinder may allow some gas to leak around the cylinder cooling it.This will result in an inadequate treatment.In this situation the dispenser should be emptied and a new cylinder and cosmetic solution vial used.

     -Do not use the device in a treament room with candies and open flames.

      Those should be eliminated during the entire procedure time.

     -Store cartridges in cool and dry areas at temperatures below 50°C(122°F).

      Keep away from direct sunlight and heat sources.Do not store in the car .

      Fluctuations in temperatures may affect the flow of the gas.Cold temperatures will slow down the flow while warm temperatures may speed up the flow of gas.



西班牙魔术焕肤枪实拍图片:

 

信息声明:本产品供应信息由仪器网为您整合,供应商为(广州传祺美容仪器有限公司),内容包括 (西班牙原装进口魔术焕肤枪哪里买)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (西班牙原装进口魔术焕肤枪哪里买)的信息,请直接联系供应商,给供应商留言!
供应商产品推荐
    您可能感兴趣的产品