| 3-INSTALLATION
| The device installation is extremely user friendly and easy:
| 1- Remove the CooLifting Gun base and the power connector from
| the briefcase.
| 2-Place the base on a flat surface in the treatment room near a power outlet.
| 3-Connect the Gun base through its front side
| to the base logo will turn on and the power
| Connector.
| 4-Place the Gun on its base to start charging
| It.the base logo will turn on and the screen
| Will display the charge action
| 5-After the gun is charged,the base logo will turn off.
| 6-Place the ”kits next to the Gun base ,so that they can be
| Easily reached when starting a treatment.
|
|
|
|
|
|
|
| 4-SESSION PREPARATION
| The following Warning screen will be displayed if the cosmetic solution
| vial and gas cartridge are not properly installed before starting a treatment. It is important to note that the the Gun will not be enabled
| until detects that everything is properly loaded
|
| 1-Take one of the treatment kits from the units display box and open it. Take the CooLifting cosmetic product bottle out and remove the blue cover.A rubber cover surrounded by a metal ring will become Visible.
|
|
|
|
| 2-Remove the gun from its base and attach the hand strap to it.
| Both the gun logo and the screen will turn on. Place the container in its place ,in the upper part of the gun ,with the rubber cover facing
| Downwards, pressing on it until needles penetrate rubber cover.
|
| 3-Remove the cartridge from its box and screw it quick and tightly on the CooLifting Gun back side ,to the top , going over the first stop ,so
| That it is secure. Never remove the cartridge by unscrewing it in this
| Phase or any other situation until the 4 full minutes of spray have
| Ended.
|
| When everything is ready.the gun will display the CooLifting screen.
|
| NOTE: if left away from the base,after two minutes it will go on to stand-by and,after 5minutes .it will turn itself off .you can leave the
| Stand-by status by pressing any button, the Gun the same state it was
| in before going into standby.if it has turned itself off, you must return
| It to the base and the CooLifting screen will be displayed again.
| You are now ready to start the treatment session.
| importANT!!
| Inserting the Cosmetic Solution:
| Press as shown in the picture below. DON’T TURN or TWIST the bottle of the cosmetic solution as it may damage the Gun
|
| Removal of the Cosmetic Solution after the Treatment Using two fingers pull the vial directly out as shown in the picture below.DON’T TURN or TWIST the bottle of the cosmetic product in order to prevent
| Damage to the Gun
|
|
| 5-THE SESSION
| Note:
| If the Gun is not going to be used immediately, do not insert a new vial of cosmetic product and cartridge into the dispenser.
| only place the cosmetic product bottle and the cartridge just prior to a treatment.
| Never place the Gun with the cosmetic product bottle and the cartridge on the charger base .once a Gun has a new vial of Cosmetic Solution and gas cartridge installed it must be emptied before it is placed back on the charger.Leaving the cosmetic solution vial in the unit will cause issues with the software .Contact Customer Service if you have any questions.Additionally,never remove the gas cartridge unless it has been used and emptied.
| HOW TO PEREORM A COOLIFTING TREATMENT:
| Clean any make-up from the patient’s face before starting .
| After having the Gun prepared with cosmetic solution and gas cartridge,invite the
| client into the treatment room. To begin the treatment, prepare the client on the
| Treatment table in a laying or half-laying position,at a height so that the Gun will
| Always point down.
To start the treatment,the“Session”screen will be displayed.in order to get started,the padlock button must be selected to unlock it.
Padlock button
After it is unlocked,press the trigger without releasing it and the warm-up screen will be displayed, with a 10 seconds count-down.After this count down the Gun
Will pulse the spray which contains the contents of the cosmetic solution and the
cool gas at the same time. The screen will display the remaining session time,counting down from 4 minutes.
If the padlock hasn’t been previously unlocked, upon pressing the trigger the padlock hasn’t been previously unlocked, upon pressing the trigger the following
Warning screen will be displayed:
The application must be done continuously always moving during the application of the cosmetic solution. The suggested dispense distance from the skin is O.5-1 cm (0.18 to 0.39 inches).If a client is uncomfortable simply move the spray further
Away from the skin.. It is recommended to have the client protect their eyes during the treatment ideally using protective glasses or a cover.Never touch the surface of the skin with the unit!
We recommend starting the treatment from the ear area toward the neck. Use small circular movements working your way around the face.Ensure you dispense
the cosmetic solution over entire face and then repeat apply on any areas of concern.The treatment must be carried on for the full 4 minutes,from start to finish,without releasing the Gun trigger and without any interruptions.Each treatment session that would lose its effect if interrupted. In the beginning the spray will be strongest and will weaken during the final minute .Clients should also
be advised about the“clicking”noise made by the Gun during the treatment.
The Gun will automatically stop at the end of the treatment session,after 4 minutes.The screen will display “End of session”and a“beep-beep”sound will
Indicate that the gas cartridge and the cosmetic solution bottle can be removed.
The sound will continue until both the gas cartridge and cosmetic solution bottle
Have been removed.
NOTE: if the trigger is released, the session pauses and restarts upon pressing the
trigger again ,with the remaining session time that was left before the interruption.
If the pause is done within a few seconds of a session,upon pressing the trigger
Again it will also restart where it was stopped , but with another 10 seconds warn
-up.
once a treatment is complete, proceed to a soft facial massage during 2-3 minutes;
It will help removing the product excess.
You should expect that a short hiss of air when unscrewing the gas cartridge after a
completed treatment. Remember:Do not remove either the cosmetic solution
bottle or gas cartridge until the full 4 minutes are done !
NOTE: The Gun must be charged after 4 to 5 treatments. The software will not
Allow you to begin treatment unless the dispenser is sufficiently charged.
6-PROTOCOL:NUMBER OF TREATMENTS AND APPLICATION ZONES
There are some general to be used as guidelines,but they must be adapted to each
clients’s desired outcomes and be its most affected zones:
-Single session: Immediate effect in a single session on symptoms, more radiant
Appearance and encouraged hydration of the skin.
-Multiple treatment protocol: 6-8 sessions in one month (1-2 per week) for a more
Youthful appearance, increased longer lasting radiant appearance, encouraged
Hydration of the skin.
-Maintenance treatment: One session every 2 weeks.
The application zones are:
-Around the eyes (do not apply on the eyelids)
-Forehead
-Brow
-Cheeks
-Zone around the lips the whole orbit round the mouth ,above, below and on both sides.
7--SAFETY WARNINGS AND PRECAUTIONS
-CO2 Gas Cartridge
- Always use the Gun with the hand strap for the duration of the treatment once the gas cartridge is inserted.
-Turn the cartridge clockwise rapidly screwing it into the dispenser.
-once inserted, do not try for any reason to unscrew the gas cartridge until the
Treatment is complete.If you think something is wrong,discharge the spray gas by pressing the trigger of the CooLifting Gun till the gas flow stops.Direct the gas flow away from yourself and be sure that the cartridge is empty before attempting to remove it.
-Improper insertion of the gas cylinder may allow some gas to leak around the cylinder cooling it.This will result in an inadequate treatment.In this situation the dispenser should be emptied and a new cylinder and cosmetic solution vial used.
-Do not use the device in a treament room with candies and open flames.
Those should be eliminated during the entire procedure time.
-Store cartridges in cool and dry areas at temperatures below 50°C(122°F).
Keep away from direct sunlight and heat sources.Do not store in the car .
Fluctuations in temperatures may affect the flow of the gas.Cold temperatures will slow down the flow while warm temperatures may speed up the flow of gas.