产品库

Human Glucose Transporter 3 (GLUT3) ELISA Kit

产品信息
  • Human Glucose Transporter 3 (GLUT3) ELISA Kit
    Product name: Human Glucose Transporter 3 (GLUT3) ELISA Kit
    Method: sandwich
    Synonyms: ErbB2; HER-2/neu; HER2; NEU; NGL; TKR1; C-Erb B2; CD340; p185;
    Catalog number: DL-GLUT3-Hu
    Detection range: 0.78 -50ng/mL
    Size: 96T
    Assay length 1-4.5Hours
    Price: inquiry
    Quality guarantee period: for 12 months
    IntroductionHuman Glucose Transporter 3 (GLUT3) ELISA Kit
    Item Standard Test Result  
    Description This immunoassay kit allows for the specific measurement of this index
    in serum, Plasma , Urine ,tissue homogenates and Cell culture supernates and Other biological fluids..
    Conform  
    Identification Colorimetric Positive  
    Composition Pre-coated, ready to use 96-well strip plate
    Standard (freeze dried)
    Standard Diluent
    Detection Reagent A
    Detection Reagent B
    Assay Diluent A
    Assay Diluent B
    TMB Substhumane
    Stop Solution
    Wash Buffer(30 x concenthumane)
    Plate sealer for 96 wells
    Instruction manual
    1
    2
    1 × 20ml
    1× 120μl
    1× 120μl
    1 × 12ml
    1 × 12ml
    1 × 9ml
    1 ×6ml
    1 ×20ml
    2
    1
    Conform
     Human Glucose Transporter 3 (GLUT3) ELISA KitTest principle

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to this index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for this index and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve

    Recovery

    Matrices listed below were spiked with certain level of recombinant the index and the recovery humanes were calculated by comparing the measured value to the expected amount of the index in samples.

    Matrix Recovery range (%) Average(%)
    serum(n=5) 81-93 86
    EDTA plasma(n=5) 80-97 88
    heparin plasma(n=5) 90-101 95
     Human Glucose Transporter 3 (GLUT3) ELISA KitLinearity

    The linearity of the kit was assayed by testing samples spiked with appropriate concenthumanion of the index and their serial dilutions. The results were demonsthumaned by the percentage of calculated concenthumanion to the expected.

    Sample 1:2 1:4 1:8 1:16
    serum(n=5) 82-96% 83-98% 81-99% 93-101%
    EDTA plasma(n=5) 88-101% 86-95% 90-102% 80-93%
    heparin plasma(n=5) 80-91% 82-90% 95-104% 79-95%
     Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Stability

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end

    Assay procedure summary

    1. Prepare all reagents, samples and standards;
    2. Add 50µL standard or sample to each well.
        And then add 50µL prepared Detection Reagent A immediately.
        Shake and mix. Incubate 1 hour at 37℃;
    3. Aspirate and wash 3 times;
    4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37℃;
    5. Aspirate and wash 5 times;
    6. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
    7. Add 50µL Stop Solution. Read at 450 nm immediately.
    DL-OPN-Hu    人骨桥素(OPN) ELISA Kit    human Osteopontin (OPN) ELISA Kit    Homo sapiens human    0.625-40ng/mL    0.234ng/mL    96T    2570    12 months
    DL-OPN-Ra    大鼠骨桥素(OPN) ELISA Kit    Rat Osteopontin (OPN) ELISA Kit    Rattus norvegicus  Rat    3.125-200ng/mL    1.32ng/mL    96T    3800    12 months
    DL-OPN-Rb    兔骨桥素(OPN) ELISA Kit     Rabbit Osteopontin (OPN) ELISA Kit    Oryctolagus cuniculus  Rabbit    0.156-10ng/mL    0.065ng/mL    96T    3800    12 months
    DL-OPN-Mu    小鼠骨桥素(OPN)  ELISA Kit    mouse Osteopontin (OPN) ELISA Kit    Mus musculus  mouse    39.063-2500pg/mL    16pg/mL    96T    2475    12 months
    DL-aCTx-Ra    大鼠α-骨胶原交联(αCTx) ELISA Kit    Rat Alpha-Crosslaps (aCTx) ELISA Kit    Rattus norvegicus  Rat    111.11-9000pg/mL    39.5pg/mL    96T    3800    12 months
    DL-DPD-Ge    脱氧吡啶酚(DPD) ELISA Kit    general Deoxypyridinoline (DPD) ELISA Kit    General    6.17-500 nmol/L    1.95 nmol/L    96T    3440    12 months
    DL-CTXIII-Hu    人Ⅲ型胶原交联羧基端肽(CTXⅢ) ELISA Kit    human Cross Linked C-Telopeptide Of Type III Collagen (CTXIII) ELISA Kit    Homo sapiens human    123.46-10000pg/mL    43.6pg/mL    96T    3530    12 months
    DL-bCTx-Hu    人β-骨胶原交联(βCTx) ELISA Kit    human Beta-Crosslaps (bCTx) ELISA Kit    Homo sapiens human    98.77-8000pg/mL    33.42pg/mL    96T    3530    12 months

  • 信息声明:本产品供应信息由仪器网为您整合,供应商为(上海康朗生物科技有限公司),内容包括 (Human Glucose Transporter 3 (GLUT3) ELISA Kit)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (Human Glucose Transporter 3 (GLUT3) ELISA Kit)的信息,请直接联系供应商,给供应商留言!
    供应商产品推荐