产品库

248H Rosemount 248 Temperature transmitter with HART protocol

产品信息
品PaiROSEMOUNT型号248H
类型热电阻温度变送器测量范围80(℃)
测量精度0.075(℃) 输出信号4-20ma
工作电压24(V)
Rosemount 3051 Pressure Transmitters With its time-tested reliability and over4 million installations, the Rosemount 3051 is more than field proven – it is the Industry Standard.The 3051 delivers unparalleled reliability, performance and safety to increase your plant profitability. Better measurement means a stronger bottom line. The comprehensive offering enhances your pressure, level and flow applications from simple measurement to stringent SIL2 safety compliance.

Measurement Type

Differential, Gage, Absolute, Level, Flow

Output

4-20 mA HART, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5 Vdc HART Low Power

Reference Accuracy

± 0.065% of span with 0.04% Optional

Total Performance

± 0.15% of span

Long Term Stability

± 0.125% of URL for 5 years

Rangedown

100:1

Rosemount 2051 Pressure TransmittersThe Rosemount 2051 family of pressure transmitters empowers you to measure pressure with confidence.The 2051 provides a reliable differential, gage, and absolute pressure measurement with a variety of output protocols, materials and process connections. Meet yourpressure,level, andflowapplication needs with its flexible Coplanar™platform so that you can lower project and ongoing maintenance costs.

Measurement Types

Differential, Gauge, Absolute, Level and Flow

Output

4-20mA HART®, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power

Reference Accuracy

± 0.075% of span

Long Term Stability

0.1% of URL for 2 years

Rangedown

100:1

Rosemount 248 Temperature transmitter with HART protocolA complete temperature assembly for any Single Point measurement applicationThe Rosemount 248 Temperature Transmitter is designed to meet common Single Point measurement application requirements. This transmitter with HART® protocol can easily be ordered with a variety of sensors (RTDs and thermocouples) and thermowells. The Rosemount 248 is provided in a head mount configuration suitable for installation in a wide variety of connection heads and housings. Additionally, a Rail Mount configuration is also available for rail and rack mountable applications. A PC-programmable interface is available, providing an easy-to-use configuration method from any PC.Ready to Install. Remove it from the Box and Install into the Process for significant cost savingsUnsurpassed Performance for Temperature Monitoring PointsIndustry StandardDIN Form BSize Enables Mounting in Any Connection HeadReliable EMC Performance by Meeting NAMUR NE 21Recommendation Communicates Using Open HART / 4-20 mA Protocol

Key Specifications

Digital Accuracy

0.20°C(0.36°F) or 0.1% of span

Ambient Temperature Effect

± 0.006°C/°C per 1.0°C (1.8°F) change in ambient (Pt100 RTD)

Stability

0.1% reading or 0.1°C (0.18°F) for 1 year

Input

2-, 3-, and 4-wire RTDs, thermocouple, millivolt, ohm

Output

2-wire, linear with temperature or input on 4-20 mA/HART signal

Supply Voltage

12 - 42.2V

Supply Voltage

12 - 42.2V in HART Protocol
9 - 32V in FOUNDATION Fieldbus Protocol

Rosemount 644 Head and Rail Mount Temperature TransmittersThe ideal temperature transmitter for any Single Point measurement application.The Rosemount 644 offers a flexible and reliable solution to any temperature measurement. As a highly accurate transmitter that comes in either HART, FOUNDATION Fieldbus or PROFIBUS PA communication protocols, or a head mount or rail mount Form Factor, the Rosemount 644 is designed to meet your most demanding applications.An available LCD display provides local measurement indication and the Transmitter-Sensor Matching functionality provides unmatched accuracy for a transmitter and RTD sensor measurement point

Digital Accuracy

+ 0.15° C (+0.27° F) for Pt100 RTD

D/A Accuracy

+0.03% of span

Ambient Temperature Effects

0.003°Cper 1.0°C (1.8°F) change in ambient (Pt100 RTD)

Stability

.15% of Reading or .15°C for 2 years

Input

2-, 3-, and 4-wire RTDs, thermocouple, millivolt, ohm

Supply Voltage

12 - 42.2V in HART Protocol

Form Factor

DIN A Head Mount or Rail Mount

Digital Accuracy

+ 0.15° C (+0.27° F) for Pt100 RTD

Ambient Temperature Effects

0.003°Cper 1.0°C (1.8°F) change in ambient (Pt100 RTD)

Stability

.15% of Reading or .15°C for 2 years

Input

2-, 3-, and 4-wire RTDs, thermocouple, millivolt, ohm

Supply Voltage

9 - 32V in FOUNDATION Fieldbus Protocol

Form Factor

Head Mount

Digital Accuracy

+ 0.15° C (+0.27° F) for Pt100 RTD

Ambient Temperature Effects

0.003°Cper 1.0°C (1.8°F) change in ambient (Pt100 RTD)

Stability

.15% of Reading or .15°C for 2 years

Input

2-, 3-, and 4-wire RTDs, thermocouple, millivolt, ohm

Supply Voltage

9 - 32V in FOUNDATION Fieldbus Protocol

Form Factor

Head Mount

信息声明:本产品供应信息由仪器网为您整合,供应商为(金华中能自动化设备有限公司),内容包括 (248H Rosemount 248 Temperature transmitter with HART protocol)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (248H Rosemount 248 Temperature transmitter with HART protocol)的信息,请直接联系供应商,给供应商留言!
供应商产品推荐