Safety Light Curtains | C2000 RES/EDM | | Receiver | Model Name | C20E-120304A31 | Part No. | 1042151 | | Sender | Model Name | C20S-120204A11 | Part No. | 1016643 | | | External device monitoring (EDM) |
| |       |
| | |
Functions-Sender |  | Beam coding: |  |  |  | Configuration method: | hard wired |  |  | Extension connection: | - |  |  | Safedevice communication via EFI/SDL: | - |  |
Functions-Receiver |  | Restart interlock: |  |  |  | External device monitoring: |  |  |  | Beam coding: | - |  |  | Muting with: | Flexi Classic, Flexi Soft |  |  | Configuration method: | hard wired |  |  | Extension connection: | - |  |  | Safedevice communication via EFI/SDL: | - |  |
 | |  |
Technical Data-Sender |  | Protective field height: | 1,200 mm |  |  | Resolution: | 40 mm |  |  | Scanning range from ... to: | 2,5 ... 19 m |  |  | Housing cross section: | 34 x 29 mm |  |  | Type: | Type 2 (IEC 61496) |  |  | Safety integrity level: | SIL 2 (IEC 61508), SILCL2 (IEC 62061) |  |  | Category: | Category 2 (EN ISO 13849) |  |  | Test rate (internal test): | 13 /s (EN ISO 13849) |  |  | Maximum demand rate: | 8 /min (EN ISO 13849), between two demands on a safety-related response of the device at least 100 internal or external tests must be carried out. |  |  | Performance Level: | PL d (EN ISO 13849) |  |  | PFHd: | 2,2 * 1E-08 |  |  | TM (Mission Time): | 20 a |  |  | Enclosure rating: | IP 65 (EN 60529) |  |  | Protection class: | III |  |  | Ambient operating temperature from ... to: | 0 ... 55 °C |  |  | Vibration resistance (checked to): | 5 g (IEC 68-2-6) |  |  | Oscillation frequency from ... to: | 10 ... 55 Hz |  |  | Shock resistance: | 10 g, 16 ms, IEC 68-2-29 |  |  | Weight: | 1.18 kg |  |  | Supply voltage typical, from, to: | 24 V DC, 19,2 V DC, 28,8 V DC |  |  | Maximum power consumption: | 6.2 W |  |  | Wave length: | 950 nm |  |  | System connection: | Plug M12 x 8 |  |  | Maximum connection cable cross-section: | 0.25 mm² |  |
 | |  |
Technical Data-Receiver |  | Protective field height: | 1,200 mm |  |  | Resolution: | 40 mm |  |  | Housing cross section: | 34 x 29 mm |  |  | Type: | Type 2 (IEC 61496) |  |  | Safety integrity level: | SIL 2 (IEC 61508), SILCL2 (IEC 62061) |  |  | Category: | Category 2 (EN ISO 13849) |  |  | Test rate (internal test): | 13 /s (EN ISO 13849) |  |  | Maximum demand rate: | 8 /min (EN ISO 13849), between two demands on a safety-related response of the device at least 100 internal or external tests must be carried out. |  |  | Performance Level: | PL d (EN ISO 13849) |  |  | PFHd: | 2,2 * 1E-08 |  |  | TM (Mission Time): | 20 a |  |  | Enclosure rating: | IP 65 (EN 60529) |  |  | Protection class: | III |  |  | Ambient operating temperature from ... to: | 0 ... 55 °C |  |  | Vibration resistance (checked to): | 5 g (IEC 68-2-6) |  |  | Oscillation frequency from ... to: | 10 ... 55 Hz |  |  | Shock resistance: | 10 g, 16 ms, IEC 68-2-29 |  |  | Weight: | 1.18 kg |  |  | Response time: | 13 ms |  |  | Supply voltage typical, from, to: | 24 V DC, 19,2 V DC, 28,8 V DC |  |  | Maximum power consumption: | 8 W |  |  | Maximum switching voltage: | Vs-2.25 V |  |  | Maximum switching current: | 500 mA |  |  | Wave length: | 950 nm |  |  | System connection: | Plug M12 x 8 |  |  | Connection type extension connection: | plug M12 x 8 |  |  | Maximum connection cable cross-section: | 0.25 mm² |  |
 | |  |
|  |  |  Show Image | |
 | Online data sheet |  |  Copy page URL |  |  Send to a friend |  |   Bookmark this page |  |
| Literature |  |  EC-DeclarationofConformity |  |  Product overview |  |  Operating Instruction |  |  Addendum operating instructions | |
| Info service |  |  CAD drawing (DXF) |  |  CAD design models | |
|  Accessories |
|  Associated Products |
|  Applications |
|  Services |
|  Connection Diagrams |
| |
|