产品库

WIKA PSA-31 卫生型 带数字显示 压力开关 IO-KINK 医药卫生用

产品信息
WIKA PSA-31 卫生型 带数字显示 压力开关 IO-KINK 医药卫生用

 

接口尺寸: G 1 Hygienic DIN 11851 Tri-clamp Clamp DIN 32676(mm) 加工定制:
防护等级: IP65 测量范围: 0-25BAR(kPa)
类型: WIKA卫生型带数显压力开关PSA-31 卫生型压力开关IO-KINK带数显头 防爆等级: ATEX
型号: PSA-31 测量介质: 液体
精度等级: 1 品Pai: WIKA/威卡
输出信号: 4-20(mA) 电源电压: 10-30(V)

WIKA PSA-31 卫生型 带数字显示 压力开关

IO-KINK 医药卫生用

Electronic pressure switch with display for sanitary applications
Model PSA-31



Pressure switch model PSA-31

 

   Applications
     Food and beverage industry
     Pharmaceutical industry
     Filling and packaging machinery
     Sanitary applications

 
   Special features
     Easily-readable, robust display
     Intuitive and fast setup
     Easy and flexible mounting configurations

   Description


   Award-winning in design and functionality
    The successful design and the excellent functionality of the WIKA switch family were already confirmed by winning the "iF product design award 2009" for the PSD-30 pressure switch.
    The robust LED display has been designed using 9 mm high characters (the largest possible) and with a slight incline in order to make reading the pressure as easy as possible from a long way off. A 14-segment display has been used, since it represents text very well.

    The 3-key operation makes simple, intuitive menu navigation possible, with no need for additional assistance. The menu navigation is designed in accordance with the latest VDMA standard. The VDMA standard for fluid sensors (24574-1, part 1 - pressure switches) has the aim of simplifying the use of pressure switches by standardising menu navigation and display.
    The control keys have been designed as large as possible and are arranged ergonomically to ensure fast and easy adjustments. Operation without any additional assistance is made easier through the tactile feedback.

 

   Customised installation
    The installation of the PSA-31 can be flexibly adapted to the individual mounting situation. Due to the almost unlimited rotation of the display and case by more than 300°, the display can be adjusted independently of the electrical connection. The display can thus always be aligned to face the operator, and the M12 x 1 connection positioned to suit the desired cable routing.


    High quality
    During development of the WIKA switch family a high value was placed on a robust design and the selection of appropriate materials suited to machine building applications. For this reason the case and the threaded connection of the electrical connector are made from stainless steel. Overwinding or tearing off the connector is therefore virtually impossible.

 

 

 

   Measuring ranges

   

    Overpressure limit
    2 times


   Display
    14-segment LED, red, 4-digit, 9 mm character size
    Display can be turned electronically through 180°


   Update
    100, 200, 500, 1000 ms (adjustable)


   Output signal

   Switching output 1      Switching output 2      Analogue signal
       PNP                      -                        4 ... 20 mA
       PNP                      -                        DC 0 ... 10 V
       PNP                      PNP                      4 ... 20 mA
       PNP                      PNP                      DC 0 ... 10 V

   Alternatively also available with an NPN instead of a PNP switching output.
    With the IO-Link option, switching output 1 is always PNP.

 

   Zero offset adjustment
    maximum 3 % of span

 


   Analogue signal
    Current output load:    ≤ 0.5 kΩ
    Voltage output load:     > 10 kΩ
    Settling time:           3 ms


   Switching output
    Switch point 1 and switch point 2 are individually adjustable
    Normally-open and normally-closed function: freely adjustable
    Window and hysteresis function: freely adjustable


   Switching voltage:  Power supply - 1 V
    Switching current:     maximum 250 mA
                           maximum 100 mA with IO-Link option
    Settling time:         ≤ 10 ms

 

   Voltage supply


   Power supply
    DC 15 ... 35 V


   Current consumption
    maximum 100 mA


   Total current consumption
    maximum 600 mA incl. switching current
    maximum 500 mA incl. switching current (with IO-Link option)


   Accuracy


   Analogue signal
    ≤ ± 1.0 % of span
   Including non-linearity, hysteresis, zero-point and full scale deviations (corresponds to measured error per IEC 61298-2). Calibrated in vertical mounting position with process connection facing downwards.


   Non-linearity
    ≤ ± 0.5 % of span BFSL (per IEC 61298-2)


   Adjustment accuracy of the switch points
    ≤ ± 0.5 % of span


   Display
    ≤ ± 1.0 % of span ± 1 digit


   Long-term drift
    ≤ ± 0.2 % of span (per IEC 61298-2)

 

   Temperature coefficients depending on the process connection


   Clamp DIN 32676, DN 32
    Typical temperature coefficient of zero point
     0 ... 20 °C          0.75 % of span / 10 K
     20 ... 80 °C         0.45 % of span / 10 K
    Typical temperature coefficient of span
     0 ... 80 °C          0.1 % of span / 10 K


   All other process connections
    Typical temperature coefficient of zero point
     0 ... 20 °C          0.7 % of span / 10 K
     20 ... 80 °C         0.2 % of span / 10 K
    Typical temperature coefficient of span
     0 ... 80 °C          0.1 % of span / 10 K


   Reference conditions
    Temperature:            15 ... 25 °C
    Atmospheric pressure:   950 ... 1050 mbar
    Humidity:               45 ... 75 % relative
    Nominal position:       Process connection lower mount
    Power supply:           DC 24 V
    Load:                   see "Output signal"

 

   Operating conditions


    Temperatures and humidity
    Ambient temperature: -20 ... +80 °C
    Storage temperature: -20 ... +80 °C
    Rated temperature range: 0 ... 80 °C
    Permissible humidity: 45 ... 75 % relative


   Ingress protection
    IP 65 and IP 67
   The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection.

   Medium temperature depending on the process connection
     G1 hygienic
        -20 ... +125 °C (+150 °C possible for up to 60 minutes)
     All other process connections
        -20 ... +100 °C (+135 °C possible for up to 60 minutes)


   Vibration resistance
    10 g (IEC 60068-2-27, vibration under resonance)


   Shock resistance
    50 g (per IEC 60068-2-6, mechanical shock)


   Process connections


   Standard                       Thread
    Hygienic                           G 1, flush 1) 2)
    Grooved union nut DIN 11851        DN 40
      with conical coupling 3)         DN 50
    Tri-clamp                          1 1/2"
                                       2"
    Clamp DIN 32676                    DN 32
                                       DN40

                                       DN 50
   1) Sealing from EPDM or FKM
    2) Suitable for WIKA adapter system model 910.61; see data sheet AC 09.20
    3) For a 3-A conform connection of process connections with milk thread fittings per DIN 11851, profile sealings from SKS Komponenten BV or Kieselmann GmbH have to be used.


   Electrical connections

 

   Connections
     Circular connector M12 x 1, 4-pin
     Circular connector M12 x 1, 5-pin 1)
   1) Only for version with two switching outputs and analogue signal

 

   Electrical safety
    Overvoltage protection:        DC 40 V
    Short-circuit resistance:      S+ / SP1 / SP2 vs. U

 

    Reverse polarity protection:   U+ vs. U

    Insulation voltage:            DC 500 V


   Connection diagram

   

   Materials


   Wetted parts
    Process connection: Stainless steel 1.4435 / 316L


   Non-wetted parts
    Case:           Stainless steel 304
    Keyboard        TPE-E
    Display window: PC
    Display head:   PC+ABS-Blend


   Pressure transmission medium
    KN59 Neobee® M-20, FDA conform


   Approvals, directives and certificates


   Certificates
    3-A (74-03)
   This instrument is 3-A marked based on a third party verification for conformance to the 3-A standard 74-03.


   CE conformity
      This instrument is a pressure accessory as defined by the
        97/23/EC pressure equipment directive.
      EMC directive 2004/108/EC, EN 61326 emission (group 1,
        class B) and interference immunity (industrial application)

 

   RoHS conformity
    Yes

 

   Available documentation and certificates
     Material certificate per EN 10204-3.1
     Confirmation of the class and indication accuracy
     FDA conformity
     Manufacturer's declaration regarding EU regulation 1935/2004 EC
    Others on request

 

   Dimensions in mm
    Pressure switch

   


 

欢迎致电WIKA PSA-31 卫生型 带数字显示 压力开关 IO-KINK  医药卫生用

电话: 56291930 15910733293

传真:

QQ:823377546 1491421115 2636968574

邮箱:sales@zoriver.cn

公司官网:http://www.zoriver.cn       http://www.zoriver.com.cn


信息声明:本产品供应信息由仪器网为您整合,供应商为(卓尔瑞华(北京)科技有限公司),内容包括 (WIKA PSA-31 卫生型 带数字显示 压力开关 IO-KINK 医药卫生用)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (WIKA PSA-31 卫生型 带数字显示 压力开关 IO-KINK 医药卫生用)的信息,请直接联系供应商,给供应商留言!
供应商产品推荐
    您可能感兴趣的产品