产品库

ERGOMETER CALIBRATOR TO 1200 WATTS 测力计校准仪 VACUMED

产品信息
  • ERGOMETER CALIBRATOR TO 1200 WATTS 测力计校准仪 vacumed
    Calibrate braking power (watts) and rpm of any stationary ergometer

    (Click on model 17810 photo to enlarge it)

    (Photo is obsolete)

     

    Provides Confidence in the Accuracy of your Test Data

    The Cycloergometer Calibrator is a portable device that measures the running torque required to rotate a crankshaft of a wide range of cycle ergometers at a selected speed to derive the breaking power in watts or Kgm.

    This is achieved by combining a powerful source of rotary motion and a precision load cell with an electronic means of control and monitoring.

    The instrument is delivered with a set of mounting and interfacing tools. Up to now there was no way to calibrate a cycle ergometer, so the question of accuracy of test data was politely ignored.

     

    Fact: The typical accuracy of the load setting of
    a cycle ergometer is 5 to 20%

    Experience has shown that many, if not most, ergometers are either inaccurate to start with or lose their accuracy over time. VacuMed's calibrator accurately measures the braking power of any ergometer up to 1500 watts. Consider the effect on the accuracy of a study where one ergometer under-reports power by 20%, the other overestimates the power by 20%.

    How to make this Calibrator pay for itself: Be the first in your area to offer a calibration service to calibrate ergometers owned by other laboratories, stress test labs, hospitals, rehab departments, etc.

    Benefits:

    • More accurate VO2 and AT (anaerobic/lactate threshold) measurements
    • Reliable data from studies involving multiple ergometers Confidence in your published data and their interpretation.

    Specifications:

    • Measured range of power: 0 to 1200 W
    • Resolution: 1 watt
    • Accuracy: +/- 0.5% or +/- 1 watt, whichever is greater.
    • Accuracy of Torque: +/- 0.01 kg.m.
    • Range of Torque Measurement: 0 to 25 kg.m.
    • Range of Cadence: 45 to 125 RPM standard.
    • Accuracy of Cadence: +/- 0.25 RPM for the range of 40 to 90 RPM, otherwise +/- 0.5 RPM.
    • Digital Display: Watts, Kg.m or RPM, switch selectable.
    • Display Resolution: For speed 0.1 RPM, for torque 0.01 kg.m.
    • Analog Signal Output: RPM, Torque (Kg.m) and Watts
    • Power Requirement: 200 - 240 VAC, 20 Amp max.
    • Adapters available for most ergometers, price includes a $500 credit towards adapter of your choice. Additional adapters extra.
    • Tool kit included
    温馨提示:不可用于临床ZL。
  • 信息声明:本产品供应信息由仪器网为您整合,供应商为(米力光国际贸易有限公司),内容包括 (ERGOMETER CALIBRATOR TO 1200 WATTS 测力计校准仪 VACUMED)的品牌、型号、技术参数、详细介绍等;如果您想了解更多关于 (ERGOMETER CALIBRATOR TO 1200 WATTS 测力计校准仪 VACUMED)的信息,请直接联系供应商,给供应商留言!
    供应商产品推荐
      您可能感兴趣的产品